Whether you’re specifying fire-rated assemblies, assessing compliance, or simply aiming for safer design, understanding fire rating classifications is key. These standards distinguish how materials and assemblies behave under fire — from flame spread and smoke development to structural integrity over time.
What is Fire Rating Classification
Fire rating classification indicates how long materials or assemblies, like walls, floors, or doors, can hold back fire, typically rated in minutes or hours (e.g., 30 minutes, 1 hour). By containing fire and smoke, these classifications play a critical role in ensuring safety, meeting building codes, and protecting the structural integrity of buildings.
Fire Rating Classification Codes and Standards
Fire resistance ratings, determined through standardized tests like ASTM E119, evaluate how long a full assembly (e.g., wall or door) can withstand fire exposure without failing structurally. Standards like NFPA 80 then reference these ratings to regulate the use of fire door assemblies in building safety systems. For your convenience, we have listed out the core NFPA 80 fire door requirements here.
In contrast, flame spread ratings, based on ASTM E84, measure how fast flames travel along the surface of a single material — not how long it holds up in fire.
Credit on Koorsen
Fire Resistance Rating
Fire resistance ratings are categorized based on the amount of time a door assembly can withstand a fire before failing. The most common classifications are:
- 30 minute fire rating
- 60 minute fire rating
- 90 minute fire rating
- 120 minute fire rating
- 180 minute fire rating
- 240 minute fire rating
Read more about fire resistance rating here.
Flame Spread Classification
Classification | Flame Spread Index | Smoke Development Rating |
---|---|---|
Class A | 0 – 25 | 450 maximum |
Class B | 26 – 75 | 450 maximum |
Class C | 76 – 200 | 450 maximum |
How Flame Spread and Fire Resistance Ratings Work Together
Many people aim to match flame spread classes (A/B/C) with fire resistance ratings (30–240 minutes). While these two classifications cannot be directly equated—as they are based on different test methods, performance criteria, and applications—they can complement each other in practical design.
Here’s how they could align in real-world use cases:
Application Area | Recommended Flame Spread Class | Recommended Fire Resistance Rating |
---|---|---|
Exit corridors, stairwells | Class A (FSI 0–25) | 60–180 minutes |
Industrial spaces, fire zones | Class A (FSI 0–25) | 60–180 minutes |
Commercial interiors (e.g., classrooms) | Class B (FSI 26–75) | 60–90 minutes |
Residential concealed areas (e.g., attics) | Class C (FSI 76–200) | 30–60 minutes |
Do you have other suggestions? Please contact us to let us know!
Waterson Fire Rated Hinges: Different Occupancy Types
Waterson Hinges offer the 3-hour UL fire-rated ability, which is suitable for almost every glass, door, and gate application. Different occupancy types require specific fire safety measures. Some examples include:
Occupancy Type | Fire Rating Classifications | Applications |
---|---|---|
Fire rated door residential | 60 minute fire resistance for walls, 20 minute fire resistance for doors | Residential door Interior door Concealed door Garage door |
Fire rated door commercial | 120 minute fire resistance for walls, 90 minute fire resistance for doors | Classroom door Commercial door Wooden door Smoke partitions |
Fire rated industrial door | 180 minute fire resistance for walls, 120 minute fire resistance for doors | Industrial door (specific to factories or warehouses) Metal dutch door |
Looking for reliable fire-rated door hinges? Click now to see how Waterson can meet your toughest safety requirements.
Waterson Self Closing Hinges for Fire Doors
Waterson fire door hinges combine an overhead closer and hinge into one attractive component with optional hold-open and door-stop features. These hinges are ideal for commercial openings, gates, and glass doors. The hinges are easily installed and adjusted to comply with ADA & ICC A117.1 requirements for opening force and to assure quiet, secure closing. Made with stainless steel, Waterson door closers meet NFPA 80 and are UL 3-hour fire-rated, as well as being one of the best door hinges for both interior and all-weather exterior openings. See all our features.
Request For Quote
Please note that Waterson closer hinges start from a size of 4″x4″. If you’re in need of smaller self-closing hinges, we’d recommend checking out some other resources! Also, we only provide single acting closer hinges. Thank you.
Recent Post
How to Adjust Gate Hinges When Self Closing Gates Go Wrong
My gate is showing hold open at 90 degrees and won’t close unless it is pushed. I don’t need and didn’t request a hold-open function— [...]
Why Flush Door Hinges Outperform Traditional Spring Hinges
Flush doors offer a sleek and modern appearance, affordability, ease of maintenance, and resistance to scratches, stains, and warping. However, they are usually made from [...]
Spring Loaded Half Door Hinges for Courtroom Divider
A courtroom divider, often referred to as a barrier door, separates different areas of the courtroom, such as the judge's bench, the witness stand, and [...]